Triple-Layer Co-Extrusion | Dry Nitrogen Curing

XLPE CCV Line

This XLPE CCV line combines triple-layer co-extrusion and dry nitrogen curing for medium- and high-voltage power cable cores. The product sheet covers copper and aluminium conductors, with reference configurations up to 132 kV.

  • Triple-layer crosshead for the conductor screen, XLPE insulation and insulation screen.
  • Non-contact sag control and synchronized haul-off for stable cable travel.
  • HV configurations with rapid cooling, rotating haul-off and PLC/HMI recipe management.
Specifications PDF

Product sheet opens in a new tab. Confirm the final configuration with your enquiry.

CCV line triple-layer extrusion section with blue extruders

XLPE CCV Line Specifications

Configuration data from the CCV product sheet. Final specifications are subject to the agreed configuration.
Technical ParameterMV Reference Configuration132 kV Reference Configuration
Cable voltage rating6–35 kV10–132 kV
Copper conductor cross-section35–630 mm²50–1,000 mm²
Aluminium conductor cross-section50–800 mm²70–1,600 mm²
Extruder screw diameters (inner screen / insulation / outer screen)65 / 150 / 90 mm100 / 200 / 120 mm
Max. insulated cable diameter75 mm120 mm
Max. cable weight per metre10 kg/m15 kg/m
Total curing and cooling tube length102 m192 m

Swipe horizontally to view all specification columns.

These are two separate reference configurations from the supplied CCV Line product sheet. Values are not interchangeable or a guarantee that every maximum can be achieved simultaneously. Confirm the cable construction, compounds, output requirement and site layout before final machine selection.

CCV line curing and cooling tube arrangement in a cable production workshop
CCV line curing and cooling tube arrangement in a cable production workshop

Information for Your Enquiry

Share your cable construction and production requirements to help select an XLPE CCV line configuration and identify what needs technical confirmation.

  1. Cable construction

    Provide the target voltage rating, copper or aluminium conductor sizes, insulation thickness and finished core diameter.

  2. Materials and production target

    Identify the screen and XLPE compounds and required output. Production speed must be confirmed for the selected cable construction.

  3. Line layout

    Share the available building layout, curing and cooling route, and pay-off and take-up requirements.

  4. Site and support

    Share the destination, power supply and installation or existing-machine support requirements.

Questions About This Machine

What are the two reference configurations?

The product sheet lists an MV configuration for 6–35 kV cable cores and a 132 kV reference configuration covering 10–132 kV. Conductor ranges, extruder sizes, cable limits and tube lengths differ between them.

Which layers does the triple-layer crosshead apply?

It applies the conductor screen, XLPE insulation and insulation screen. The line uses dry nitrogen curing; the final process and machine configuration must be confirmed for the specified cable.

How can I request a configuration review?

KINGSTRONG coordinates machine sourcing and technical communication with partners in China. Share your cable and production requirements through the Contact Us page; the final scope and specifications are confirmed in the quotation.