Triple-Layer Co-Extrusion | Dry Nitrogen Curing
XLPE CCV Line
This XLPE CCV line combines triple-layer co-extrusion and dry nitrogen curing for medium- and high-voltage power cable cores. The product sheet covers copper and aluminium conductors, with reference configurations up to 132 kV.
- Triple-layer crosshead for the conductor screen, XLPE insulation and insulation screen.
- Non-contact sag control and synchronized haul-off for stable cable travel.
- HV configurations with rapid cooling, rotating haul-off and PLC/HMI recipe management.
Product sheet opens in a new tab. Confirm the final configuration with your enquiry.

XLPE CCV Line Specifications
| Technical Parameter | MV Reference Configuration | 132 kV Reference Configuration |
|---|---|---|
| Cable voltage rating | 6–35 kV | 10–132 kV |
| Copper conductor cross-section | 35–630 mm² | 50–1,000 mm² |
| Aluminium conductor cross-section | 50–800 mm² | 70–1,600 mm² |
| Extruder screw diameters (inner screen / insulation / outer screen) | 65 / 150 / 90 mm | 100 / 200 / 120 mm |
| Max. insulated cable diameter | 75 mm | 120 mm |
| Max. cable weight per metre | 10 kg/m | 15 kg/m |
| Total curing and cooling tube length | 102 m | 192 m |
Swipe horizontally to view all specification columns.
These are two separate reference configurations from the supplied CCV Line product sheet. Values are not interchangeable or a guarantee that every maximum can be achieved simultaneously. Confirm the cable construction, compounds, output requirement and site layout before final machine selection.

Information for Your Enquiry
Share your cable construction and production requirements to help select an XLPE CCV line configuration and identify what needs technical confirmation.
Cable construction
Provide the target voltage rating, copper or aluminium conductor sizes, insulation thickness and finished core diameter.
Materials and production target
Identify the screen and XLPE compounds and required output. Production speed must be confirmed for the selected cable construction.
Line layout
Share the available building layout, curing and cooling route, and pay-off and take-up requirements.
Site and support
Share the destination, power supply and installation or existing-machine support requirements.
Questions About This Machine
What are the two reference configurations?
The product sheet lists an MV configuration for 6–35 kV cable cores and a 132 kV reference configuration covering 10–132 kV. Conductor ranges, extruder sizes, cable limits and tube lengths differ between them.
Which layers does the triple-layer crosshead apply?
It applies the conductor screen, XLPE insulation and insulation screen. The line uses dry nitrogen curing; the final process and machine configuration must be confirmed for the specified cable.
How can I request a configuration review?
KINGSTRONG coordinates machine sourcing and technical communication with partners in China. Share your cable and production requirements through the Contact Us page; the final scope and specifications are confirmed in the quotation.